Quality Inspection Report for SPC Flooring Product Category Stone Plastic Composite (SPC) Flooring Country of Origin Changzhou, China Target Markets United States & Canada Inspection Date January 12, 2025 Inspection Standards

Quality Inspection Report for SPC Flooring
Product Category: Stone Plastic Composite (SPC) Flooring
Country of Origin: Changzhou, China
Target Markets: United States & Canada
Inspection Date: January 12, 2025
Inspection Standards:

  • ASTM F3261 (SPC Flooring Performance Standards)
  • ASTM E84 (Surface Burning Characteristics / Fire Resistance)
  • DIN 51130 (Slip Resistance Testing)
  • CARB Phase II (Formaldehyde Emissions)
  • CPSC 16 CFR Part 1303 (U.S. Lead Content Limits)
  • SOR/2016-193 (Canada Formaldehyde Emission Limits)
  • ASTM D4060 (Taber Abrasion Test)
  • UL 723 (Flame Spread and Smoke Density)
  • Patent Compliance (Unilin/Valinge Locking System Verification)

1. Product Description

  • Model Number: [Insert]
  • Dimensions:
  • Thickness: 6.0 mm (SPC core: 4.8 mm + wear layer: 1.2 mm)
  • Width/Length: [Insert]
  • Materials:
  • Core Layer: Stone Plastic Composite (65% limestone, 25% PVC, 10% stabilizers).
  • Surface: UV-cured wear layer with embossed wood-grain decorative film (anti-slip texture).
  • Backing: IXPE foam underlayment (2.0 mm, noise-reducing).
  • Locking System: Unilin/Valinge 5G click-lock (patent license code: [Insert]).
  • Packaging: Corrugated cartons with edge protectors, moisture-resistant film.

2. Inspection Summary

2.1 Locking System & Patent Compliance

  • Locking Type: Confirmed as Unilin/Valinge-patented 5G click system (license documentation verified).
  • Patent Clearance: No infringement detected via USPTO/CIPO database checks.
  • Functional Testing:
  • Tensile Load: 1,600 N (no joint separation).
  • Cyclic Load Test: 20,000 cycles (no failure).

2.2 Structural Strength

  • Dimensional Stability:
  • Thermal Expansion: ≤0.03% after 72h at 85°C (ASTM F3261 compliant).
  • Compressive Strength: 13,500 psi (exceeds ASTM F3261 requirements).
  • Impact Resistance: Passed 1.5kg steel ball drop (2m height, no cracks).

2.3 Surface Quality

  • Abrasion Resistance:
  • Taber Abraser (ASTM D4060): 7,500 cycles (H-18 wheel, 1kg load) – wear layer intact.
  • Steel Wool Test: 2,500 cycles (Grade 0000) – no visible scratches.
  • Color & Texture Matching:
  • ΔE Value (D65 Light): ≤0.6 (measured across 150 samples).
  • Embossing Depth Alignment: 97% match to decorative film pattern.

2.4 Water Resistance

  • 72h Water Immersion:
  • Thickness Swelling: 0.015% (ASTM F3261 compliant).
  • Edge Curling: None observed.
  • Humidity Cycling (5 cycles): No delamination or warping.

2.5 Fire Resistance

  • Flame Spread Index (FSI): ≤15 (ASTM E84 Class A).
  • Smoke Developed Index (SDI): ≤50 (UL 723 compliant).
  • Ignition Resistance: Passed 30-second direct flame exposure (no sustained burning).

2.6 Slip Resistance

  • Dynamic Coefficient of Friction (DCOF): ≥0.55 (DIN 51130, R10 rating).
  • Ramp Test (DIN 51130): Passed 12° incline (barefoot/wet condition).

2.7 Chemical Compliance

  • Formaldehyde Emission: 0.003 ppm (CARB Phase II & SOR/2016-193 compliant).
  • Phthalates (DEHP/DBP): <0.05% (CPSC & Canada CPSA compliant).
  • Lead/Cadmium Content: <20 ppm (CPSC 16 CFR Part 1303 compliant).

2.8 Packaging & Labeling

  • Carton Drop Test: Passed ISTA 3A (1.5m drop, no damage).
  • Label Compliance:
  • U.S.: “CARB Phase II Certified,” “Patent License: Unilin/Valinge [Insert].”
  • Canada: Bilingual (English/French) – “Fire Class A,” “Slip Resistance R10.”
  • Flooring Class (AC5), installation guidelines included.

3. Non-Conformities (5% of Batch)

  • Minor Defects:
  • 8/200 planks exhibited slight embossing-texture mismatch.
  • 5/200 cartons lacked bilingual fire rating labels.
  • Resolution:
  • Defective planks replaced; labels reprinted and re-verified.

4. Conclusion

The SPC flooring achieved a 95% pass rate, meeting all critical requirements for patent compliance, structural strength, surface durability, waterproof/fireproof performance, slip resistance, and environmental regulations. Approved for shipment to the U.S. and Canadian markets.

Inspector: [Name/Signature]
Approval: [Quality Manager/Signature]
Company Stamp: [Insert]


Note: This report is valid until January 11, 2026. Retesting required for material/formula changes.