CHINESE OUTDOOR STANDARD WOOD PLASTIC COMPOSITE FLOORING QUALITY CONTROL INSPECTION CHECKLIST

SCOPE  

This standard specifies the requirements of WPC floor for export, test methods, inspection rules and packaging, transportation and storage requirements. 

 

TECHNICAL REQUIREMENTS 

Size And Deviation 

Length0~+10mm, Negative tolerance is not allowed
Width±1mm, the difference between the maximum and minimum values ≤3 mm
Thicknessthickness<25mm, ±0.5mm
thickness≥25mm,±1.0mm
Tolerance on wall thickness±0.5mm
Structurewood plastic composite
Bevelneed negotiation by the Customer and factory
Straight Angle≤ 0.30mm
Straightness≤ 1.0mm
Model of clickshould be the same as the confirmed steel model
Note:No tongue WPC flooring does not required height difference and gap; If have tongue and groove, the width of tongue should be more than 3mm.For wpc flooring, the weight should be more than 95% of WPC weight which two parts agreed.

 

WPC Flooring Appearance & Quality Requirements 

In addition to the design effect, the color should be uniform, the surface is flat, no scratch, no obvious concave and convex, the impurity, the end should be straight, no burr.

ItemSuperior productQualified product
Color unmatchingIt is allowed if not too obvious
Surface unevennessNot allowedIt is allowed if not too obvious
Split, crackNot allowed
Spots,dirt and similar surface defects≤4mm², allowable amount is 1pc/m≤4mm², allowable amount is 3pcs/m
BlisterNot allowed
BubbleNot allowed
Trace grainNot allowedIt is allowed if not too obvious
Surface granularNot allowedIt is allowed if not too obvious
Incomplete sander-polishingNot allowed
Tongue and corner deformityNot allowed
The board face concave and convex is only used for judging the plane plastic wood floor

 

WPC Flooring Physical And Chemical Performance Requirements  

Test ItemTest methodStandard
 Water absorption of 24hAt room temperature, the immersion time of the sample was 24h±15min≤2.0%
 State after heating( 120℃)(120±2)℃,(30+3)minNo bubbles, cracks, pitting
 Size change rate after heating(100℃)(100±2)℃,(60+3)min±1.0%
Density ≥1.2g/cm³
surface abrasion resistance 100*100*1pc sample, install it on the wear tester. When grinding wheel weight (27±2) g, width (51.4±0.6) mm, sand paper 180#0/3 condition, wear 100 turns, remove the specimen from the surface and weigh it≤0.10g/100r
Shore hardness (D type)GB/T2411≥60
nail-holding abilitysurfaceGB/T 17657-1999≥1300N
 side≥1200N
Four point bending strengthQB/T 4161-2011 (appendix)A≥18Mpa
Four point flexural modulus of elasticity≥1800Mpa
Freeze thawing resistance24h in room temperature water, then put in ( -29±1) ℃24h, finally put 24h in room temperature environment, then place room temperature 24h, measure bending strength loadNo skin, no crack, bending strength retention ≥90%
degradation testing (1000h)The black label temperature is (65 + 3) C, relative humidity is (50 + 5)%, irradiance is 0.35W/m2@340nm, continuous illumination. Cycle period is 120min, where 102min does not spray water, 18min spray water, aging time is 1000h.The surface of the sample should not be seen by the naked eye, the skin or the crack, the hollow and the uneven color change.色差color difference:ΔE≤9
Formaldehyde releaseGB/T17657-1999≤0.5mg/L
可溶性铅含量Soluble lead contentQB/T 4161-2011≤90mg/kg
1. Not test the nail holding ability of a hollow WPC2. Not test flexural strength and flexural modulus of elasticity when the WPC thickness over 50mm3. Should grinding treatment of flooring surface when test degradation testing surface color change

 

PACKING 

Product Mark

Before the products are stored, they should be tagged in proper parts with their product models, trademarks, production dates, etc.

Packing Mark

The standard codes , factory name, address, product name, production date, trademarks, specifications, formaldehyde release sign, type, grade, quantity, etc.

Package

Should be fastened firmly, with plastic film or other soft material package, you need to use other special packing methods agreed by both sides of supply and demand.

Transport

It should be flat and stacked to avoid heavy pressure, rain prevention and sunscreen, light load and light load.